Difference between revisions of "Programmable Chip EEG"

From OpenCircuits
Jump to navigation Jump to search
Line 25: Line 25:
  
 
The resulting analog signals will be passed into a digital circuit, based on the Cypress [[PSoC microcontrollers]], which will digitize the signals, further process them, and provide an interface to a computer.
 
The resulting analog signals will be passed into a digital circuit, based on the Cypress [[PSoC microcontrollers]], which will digitize the signals, further process them, and provide an interface to a computer.
 +
 +
 +
== Open Source Circuit Design ==
 +
[http://opencircuits.com/Programmable_Chip_EEG Open Source Circuit Design ]
 +
[http://www.thinkcycle.org/ Think Cycle]
 +
 +
== Open source (public) results! ==
 +
PHP will be used to create a database of users and what they sample and choose to share with the open source community.
 +
 +
The database will give statistical analysis on users recordings.
 +
 +
Also the extension of SETI called BIONIC could be used as a distributed library creation of artifacts and data mining.
 +
 +
Please contribute and make the PCEEG a great tool for researching brain computer interfaces.

Revision as of 09:50, 20 July 2006

The Programmable Chip EEG

Welcome to the PCEEG Wiki, where everyone can add to this EEG brain-computer interface!

What it is and what it can be used for

The Programmable Chip EEG is a Modular Multi-channel electroencephalograph that could be used for a brain-computer interface, biofeedback....

The Programmable Chip EEG is programmable because it uses Digitally Programmable Potentiometers. They are used to set the Gain, frequency range, and can calibrate multiple analog boards for different EEG tests.

Discription of How it Works

The differential analog signal is amplified by the instramentation amplifier. Then the signal is amplified and conditioned by high pass and low pass filters.

The common mode signal is inverted summed and sent back to the body to decrese common mode signal thsi is done by the driver right leg circuit.

Band reject filters may be added soon in the future.

Then the analog signals are simultaniously digitized and the digital values can be clocked to the digital board.


Parts used in the PCEEG:

To reduce noise in the readout of the analog part of this circuit, a common-mode feedback is passed back into the body by the driver right leg circuit. Band reject filter may also be used (to reject, for example, 60Hz noise from nearby A/C power wiring).

The resulting analog signals will be passed into a digital circuit, based on the Cypress PSoC microcontrollers, which will digitize the signals, further process them, and provide an interface to a computer.


Open Source Circuit Design

Open Source Circuit Design Think Cycle

Open source (public) results!

PHP will be used to create a database of users and what they sample and choose to share with the open source community.

The database will give statistical analysis on users recordings.

Also the extension of SETI called BIONIC could be used as a distributed library creation of artifacts and data mining.

Please contribute and make the PCEEG a great tool for researching brain computer interfaces.